• integrated circuit temperature sensor
• connection cable 5.0 m
• measurement range: -40 °C ... 65 °C (-40 °F ... 149 °F)
• incl. plate radiation shield (UV-stabilized thermoplastic)
• signal type: linear analog voltage
• accuracy: ±1.24°C (±2.23°F) at an uncertainty k=2
• electrical time constant: 250 µs
• output signal range (DC): 0.835 V ... 2.725 V DC
• incl. hose clamps for tower mounting
Datasheet[TAB:Alternative Types available]-[TAB:Documents]-
• calibrated
• integrated circuit temperature sensor
• connection cable 5.0 m
• measurement range: -40 °C ... 65 °C (-40 °F ... 149 °F)
• incl. plate radiation shield (UV-stabilized thermoplastic)
• signal type: linear analog voltage
• accuracy: ±0.43°C (±0.77°F) at an uncertainty k=2
• electrical time constant: 250 µs
• output signal range (DC): 0.835 V ... 2.725 V DC
• incl. hose clamps for tower mounting
Datasheet[TAB:Alternative Types available]-[TAB:Documents]-
Service Includes:
• Inspection
• Inspection report
Subsequent to an inspection, the Client can decide if the sensor shall receive a Certified Maintenance and Refurbishment Service or, if needed, repair.
Service Packing List Form
[TAB:Alternative Models]Anemometer:
ARS-TFCA-CAL: Thies First Class Anemometer Service - Certified Maintenance, Inspection and Refurbishment
FIX-TFCA-CAL: Thies First Class Anemometer Service - Certified Repair
Wind Vanes:
ARS-TFCWV-CAL: Thies First Class Wind Vane Service - Maintenance, Inspection and Refurbishment
IS-TFCWV-SEN: Thies First Class Wind Vane Service - Inspection
FIX-TFCWV-CAL: Thies First Class Wind Vane Service - Certified Repair
For further information please contact us or look at Documents.
Our laboratory also performs service for anemometer and wind vane types from other manufacturers.
Please contact us with your specific request or need.
[TAB:Documents]
Please find here the Packing List Form needed for dispatching sensors to ProfEC Ventus Laboratory for Calibration, Inspection, Refurbishment or Repair Services:
Packing List Form.docx
Packing List Form.pdf
Bird Wire for Young 52202 and 52203
• Accessory to discourage birds from perching on the funnel rim
Datasheet
[TAB:Alternative Types]
For further information please contact us or look at Documents. [TAB:Documents]52202H-90.pdf
R. M. Young Tipping Bucket Rain Gauge-Models 52202-52203 Overview.pdf
Rain Gauge Sensor Young Intro Sheet.pdf
52202-90(J).pdf
For further information please contact us or check the OEM homepage for most recent information.
Cables (shielded) including mounting of connector(s) / plugs / jacks for sensors bought
• per /5m
• Shielded LiYCY x*0.5mm^2 (about 20 gauge)
• Includes mounting of sensor-specific connectors / plugs / jacks
• Sensor-specific wiring scheme included
• Line-to-line calibration according to IEC, MEASNET and FGW recommendations
• Length configured according to measurement heights
• Labelling provided for easy plug&play installation on site
Datasheet
During the order process "field: comments" please let us know, which sensor you plan to install at what height! Please thereby also take into account the length of the booms always when selecting the cable length accordingly.
The price mentioned includes the fitting of a corresponding, sensor-specific standard plug (jack or connector), if being default scope of the sensor delivery. The price mentioned includes an additional set of connectors (male and female) being confectioned as part of the (extension) cable ordered here, in case the sensor, for which the cable is ordered, by default has open-ended wires and no connector is plugged directly to the sensor.
If a cable is ordered only but without sensor, 10 EUR will be charged additionally per connector to be fitted to the cable (male or female).
[TAB:Documents]
For further information please contact us.[TAB:Alternative Models]
LiYCY UV
For further information please contact us or look at Documents.
Campbell Scientific CR1000 Data Logger
• 16x analogue single-ended or 8 differential IN
• 2x digital pulse counters IN
• 8x digital IN/OUT
• 3x analogue voltage OUT
• 1x switched 12V OUT
• RS232
• CS I/O PORT, SDI-12, Peripheral ports
• CF-card, USB, LAN, WLAN (optional)
• 2/4 Mbytes SRAM memory
• Surge protection for all Inputs by gas discharge tube (GDT)
• Surge protection for critical outputs by GDT or transient voltage suppression diodes
• Power feeding protected by transzorb diodes
• Grounding socket for electrostatic discharge (ESD) protection
• The datalogger comes embedded into a mobile measurement system for ambient temperature measurements and includes:
- power supply
- temperature sensor
- data logger programming
Further options can optionally be booked, for example more sensors, (communication) interfaces and/or data logger programming.
Datasheet
[TAB:Alternative Types]CR1000Cal
CR1000X
For further information please contact us or look at Documents. [TAB:Documents]cr1000-manual-2015.pdf
cr1000-Specifications.pdf
Datalogger-b-overview.pdf
For further information please contact us or check the OEM homepage for most recent information.
For Thies and Vector Instruments (Windspeed Ltd.) anemometer
Service Includes:
• Maintenance and Inspection
• Inspection report
• Authorised refurbishment
• Exchange of bearings, O-rings, sealings
• Certificate
• Authorisation seal
Note: after any maintenance or refurbishment service, the sensor must be compulsorily calibrated.
Service Packing List Form
Our laboratory also performs service for anemometer and wind vane models from other manufacturers. Please contact us with your specific request or need.
[TAB:Alternative Models]Anemometer:
IS-TFCA-SEN: Thies First Class Anemometer Service - Inspection
FIX-TFCA-CAL: Thies First Class Anemometer Service - Certified Repair
Wind Vanes:
ARS-TFCWV-CAL: Thies First Class Wind Vane Service - Maintenance, Inspection and Refurbishment
IS-TFCWV-SEN: Thies First Class Wind Vane Service - Inspection
FIX-TFCWV-CAL: Thies First Class Wind Vane Service - Certified Repair
For further information please contact us or look at Documents.
Our laboratory also performs service for anemometer and wind vane types from other manufacturers.
Please contact us with your specific request or need.
[TAB:Documents]
Please find here the Packing List Form needed for dispatching sensors to ProfEC Ventus Laboratory for Calibration, Inspection, Refurbishment or Repair Services:
Packing List Form.docx
Packing List Form.pdf
Discharge kit "Standard"
• IEC and MEASNET conform lightning arrestor
• 30° protection umbrella
• Distance lightning rod to top-sensor 50>D
• Deep grounding mast anchors
• For electrostatic discharge
• Basic surge, overvoltage and overload protection
[TAB:Alternative Types]Surge-ADV
Surge-PREM
For further information please contact us or look at Documents. [TAB:Documents]
For further information please contact us or check the OEM homepage for most recent information.
Cable Length (with connector):
Ohne Kabel (+0 EUR)
• sensor range: 0 W/m² to 3000 W/m²
• spectral range: 400 to 1100 nm
• incl. calibration certificate (calibrated against Eppley Precision Spectral Pyranometer (PSP) under natural daylight conditions. Absolute uncertainty under these conditions is +/-3 % typical, +/-5 % maximum)
• output signal range: 0 µA to 225 µA, typical
• sensitivity: typically 75 µA per 1000 W/m²
• linearity: max. deviation of 1 % up to 3000 W/m²
• temperature Dependence: ± 0.15% per °C maximum
• cosine Correction: Cosine corrected up to 82° angle of incidence
• azimuth: < ± 1% error over 360° at 45° elevation
• for Global Horizontal Irradiance (GHI) measurements (W/m2)
• operating temperature range: -40 °C to 65 °C (-40 °F to 149 °F)
• incl. leveling base
• incl. 2 m (6.6') cable.
Datasheet[TAB:Alternative Types available]-[TAB:Documents]-
Lockable metal shelter box / control cabinet and assembly
• Complete internal wiring, clamps, etc. ready for plug&play
• Includes terminal connectors and internal wiring to connect sensors, modem, data logger, charge controller and power supply also included
• Incl. mounting of other, ordered equipment from One Stop Wind Shop like barometer, modem, data logger, charge controller, battery, etc.
• Individual ground / earthing conductor lug for sensor mounting plate and shields (needed for galvanic separation of measurement system and cabinet from mast structure)
• Mast support & mounting equipment
• Individual connection scheme provided
• Approx. 500 x 700mm
• IP 56 / IP 66
Datasheet
[TAB:Alternative Types]Shelter-SSC
Shelter-POLY
For further information please contact us or look at Documents. [TAB:Documents]
For further information please contact us or check the OEM homepage for most recent information.
Power Supply System "Standard"
Feeds measurement system
• Mounted into existing system control cabinet / shelter box
• 1x solar charge controller and regulator Solarix PR1010
• 1x 12V battery, 50 Ah, maintenance free, non-spillable, incl. safety data sheet for aviation transport (VRLA-AGM)
• 1x solar panel 50Wp (3.0 m cable) incl. slope-adjustable mounting rack and mast support
Documents & Data Sheets
[TAB:Alternative types]PWR-ADV
PWR-SECSTD
PWR-SECADV
PWR-HEAT
For further information please contact us or look at Documents. [TAB:Documents]Charge Controller:
PR1010-Datasheet-engl.pdf
PV Module:
40W-36P POLY crystalline Solar PV Panel.pdf
50W-36P POLY crystalline solar PV panel.pdf
Adjustable PV Bracket.pdf
Adjustable PV Bracket 2.pdf
Battery:
QB-Export-12LCP-50.pdf
Savety-Data-Sheet-AGM-en-1.pdf
Q-Batteries-neutral-12LCP-50 Data Sheet.pdf
Savety-Data-Sheet-AGM-Q-Batteries-de.pdf
Enclosure:
Rittal-Technical-System-Catalogue-Compact-Enclosures-AE-engl.pdf
Rittal-Technical-System-Catalogue-Plastic-Enclosures-engl.pdf
Cable:
LiYCY 5x0.5 Data Sheet.pdf
LiYCY 5x0.5.pdf
For further information please contact us.
R. M. Young Gill Propeller Anemometer: 27106
• Expanded Polystyrene Propeller (EPS): 08274
• Diameter: 22 cm
• Pitch: 29.4 cm air passage per revolution
• Range axial flow: 0-30 m/s (70 mph)
• Threshold: 0.3 m/s (0.6 mph)
• Distance constant: 1.0 m (3.2 ft)
• Transducer: DC generator (single direction)
• Self-powered
• Mounting with MS type connector: ¾″ (26.9mm) pipe thread adapter
Datasheet
[TAB:Alternative Types]
27106T
27106DT
27106FT
For further information please please contact us or look at Documents.
[TAB:Documents]Boom-Specs-GILL-PROPELLER-ANEMOMETER-27106.pdf
Adapter-27156A-dimensional drawing.pdf
GILL-PROPELLER-ANEMOMETER-27106D-90(A).pdf
GILL-PROPELLER-ANEMOMETER-27106DT-90(A).pdf
GILL-PROPELLER-ANEMOMETER-27106T-90(C).pdf
GILL-PROPELLER-ANEMOMETER-27106DT-FT_90(A)
For further information please contact us or check the OEM homepage for most recent information.
• calibrated
• resolution: 0.254 mm (0.01 inches) of rain
• accuracy: +/- 2%, up to 50.8 mm (2 inches) per hour
• scale: 0.254 mm (0.01 inches) of rain per switch closure
• switch closure (momentary single pole, normally open (SPNO) contact), typical closure time is 0.1 second
• operating temperature: 0 °C to 45 °C
• incl. 7m (24 feet) cable
• materials: Anodized and powder-coated aluminum, thermoplastic, stainless steel fasteners
Datasheet
[TAB:Alternative Types available]-[TAB:Documents]R._M._Young_Tipping_Bucket_Rain_Gauge_-_Models_52202-52203_Overview.pdf
Rain_Gauge_Sensor_Young_Intro_Sheet.pdf
• polymer capacitor humidity sensor
• measurement range: 0 to 100% relative humidity (non-condensing)
• operating range: -40°C to 70°C (-40°F to 158°F)
• incl. 1.5m cable
• signal type: linear analog voltage
• accuracy:
+/- 2% RH (k=2) from 10% to 90% RH @ 25°C (77°F)
+/- 3% RH (Maximum) from 5% to 10% RH and 90% to 95% RH@ 25°C (77°F)
• output signal range (DC): 0 ... 5V for 0 ... 100% RH, with a load resistance greater than 10 k ohms
• incl. hose clamps for tower mounting
• UV stabilized polycarbonate plastic box with galvanized steel mounting bracket
• excellent linearity and sensitivity with fast response time and long-term stability
Datasheet[TAB:Alternative Types available]-[TAB:Documents]-
• calibration certificate (NIST-traceable)
• polymer capacitor humidity sensor
• measurement range: 0 to 100% relative humidity (non-condensing)
• operating range: -40°C to 70°C (-40°F to 158°F)
• incl. 1.5m cable
• signal type: linear analog voltage
• accuracy:
+/- 2% RH (k=2) from 10% to 90% RH @ 25°C (77°F)
+/- 3% RH (Maximum) from 5% to 10% RH and 90% to 95% RH@ 25°C (77°F)
• output signal range (DC): 0 ... 5V for 0 ... 100% RH, with a load resistance greater than 10 k ohms
• incl. hose clamps for tower mounting
• UV stabilized polycarbonate plastic box with galvanized steel mounting bracket
• excellent linearity and sensitivity with fast response time and long-term stability
Datasheet[TAB:Alternative Types available]-[TAB:Documents]-
Surge Protection Kit "Premium" for Measurement System Channels
• Surge protection (over-voltage and -currency) module (1 line or signal)
• Protection possible for each single input channel
• Rated voltage (DC) 34 V
• Rated current 500 mA
• Max. continuous voltage, Uc (DC) 42 V
• Discharge current In (8/20 μs) wire-PE 2.5 kA
• Fuse, max. 0.5 A
• Discharge current Imax (8/20 μs) wire-PE 10 kA
Datasheet
[TAB:Alternative Types]
For further information please contact us or look at Documents. [TAB:Documents]Surge-Protection-VSSC4-SL-24VAC-DC-0.5A-en.pdf
For further information please contact us or check the OEM homepage for most recent information.
Thies Compact: 4.3129.00.712
• Potentiometer 0 … 2.0 kOhm
• Measurement range: 0...360°
• Dead band: without north gap
• Resolution: 0.5°
• Accuracy: 0.5% (±2°)
• With heating (24V AC / DC, 20W)
• Power Supply: 0 ... 24 V DC
• Survival speed: max. 80m/s (≤ 30min)
• IP 55
Datasheet
[TAB:Alternative Types]4.3129.00.141
4.3129.00.161
4.3129.00.167
4.3129.00.173
4.3129.00.740
4.3129.00.741
4.3129.00.761
4.3129.00.767
4.3129.00.773
4.3129.00.940
4.3129.00.941
4.3129.02.141
4.3129.04.767
4.3129.05.140
4.3129.05.141
4.3129.39.141
4.3129.04.712
4.3129.10.712
4.3128.xx.000
.00.
.10.
4.3129.00.000
4.3129.60.000
4.3129.00.140
4.3129.00.700
4.3129.60.xxx
.140
.141
.161
.167
.173
4.3129.60.xxx
.740
.741
.761
.767
.773
4.3129.6x.xxx
4.3129.80.xxx
4.3129.0x.xxx
For further information please contact us or look at Documents.
[TAB:Documents]Thies-Compact-Wind-Vane-Poti-4.3129.xx.712.pdf
For further information please contact us or check the OEM homepage for most recent information.
Thies First Class Advanced Anemometer: 4.3351.00.140
• Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Worldwide the first Class S 0.5 anemometer according IEC 61400-12-1 Ed.1 & Ed.2, ISO 17713-1, MEASNET
• Calibrated according to MEASNET and IEC 61400-12-1 Ed.2 (ilac-MRA)
• Frequency output (1082 Hz at 50 m/s)
• Analogue output (0 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC
• With heating (24V AC/DC, 24W)
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or 0.99999 (4...20 m/s)
• IP 55
• 2 years warranty
Datasheet
Hint: please do not forget to order a sensor cable (by default this comes incl. connector mounting) at the length needed: cable w/ connector[TAB:Alternative Models]
4.3351.00.000
4.3351.00.141
4.3351.00.161
4.3351.10.000
4.3351.10.140
4.3351.10.141
4.3351.10.161
For further information please contact us or look at Documents.
[TAB:Documents]4.3351.x0.140-173_Wind_Transmitter_First_Class_Advanced_analogue_eng.pdf
4.3351.x0.140-173_WG-Geber-firstclass-advanced_analog_deu.pdf
Thies-First-Class-Advanced-Data-Sheet-Brief-en.pdf
For further information please contact us or check the OEM homepage for most recent information.
Thies First Class Advanced Anemometer: 4.3351.00.141
• Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Worldwide the first Class S 0.5 anemometer according IEC 61400-12-1 Ed.1 & Ed.2, ISO 17713-1, MEASNET
• Calibrated according to MEASNET and IEC 61400-12-1 Ed.2 (ilac-MRA)
• Frequency output (1082 Hz at 50 m/s)
• Analogue output (4 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC
• With heating (24V AC/DC, 24W)
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or 0.99999 (4...20 m/s)
• IP 55
• 2 years warranty
Datasheet
Hint: please do not forget to order a sensor cable (by default this comes incl. connector mounting) at the length needed: cable w/ connector[TAB:Alternative Models]
4.3351.00.000
4.3351.00.140
4.3351.00.161
4.3351.10.000
4.3351.10.140
4.3351.10.141
4.3351.10.161
For further information please contact us or look at Documents.
[TAB:Documents]4.3351.x0.140-173_Wind_Transmitter_First_Class_Advanced_analogue_eng.pdf
4.3351.x0.140-173_WG-Geber-firstclass-advanced_analog_deu.pdf
Thies-First-Class-Advanced-Data-Sheet-Brief-en.pdf
For further information please contact us or check the OEM homepage for most recent information.
Thies First Class Advanced Anemometer: 4.3351.00.161
• Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Worldwide the first Class S 0.5 anemometer according IEC 61400-12-1 Ed.1 & Ed.2, ISO 17713-1, MEASNET
• Calibrated according to MEASNET and IEC 61400-12-1 Ed.2 (ilac-MRA)
• Frequency output (1082 Hz at 50 m/s)
• Analogue output (0 ... 10 V = 0.3...75 m/s)
• Supply 15 ... 24 V DC
• With heating (24V AC/DC, 24W)
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or 0.99999 (4...20 m/s)
• IP 55
• 2 years warranty
Datasheet
Hint: please do not forget to order a sensor cable (by default this comes incl. connector mounting) at the length needed: cable w/ connector[TAB:Alternative Models]
4.3351.00.000
4.3351.00.140
4.3351.00.141
4.3351.10.000
4.3351.10.140
4.3351.10.141
4.3351.10.161
For further information please contact us or look at Documents.
[TAB:Documents]4.3351.x0.140-173_Wind_Transmitter_First_Class_Advanced_analogue_eng.pdf
4.3351.x0.140-173_WG-Geber-firstclass-advanced_analog_deu.pdf
Thies-First-Class-Advanced-Data-Sheet-Brief-en.pdf
For further information please contact us or check the OEM homepage for most recent information.
Thies First Class Advanced Anemometer: 4.3351.10.141
• Class A compliance in accordance to IEC 61400-12-1 and 61400-12-1 Ed.2
• Worldwide the first Class S 0.5 anemometer according IEC 61400-12-1 Ed.1 & Ed.2, ISO 17713-1, MEASNET
• Calibrated according to MEASNET and IEC 61400-12-1 Ed.2 (ilac-MRA)
• Frequency output (1082 Hz at 50 m/s)
• Analogue output (4 ... 20 mA = 0.3...75 m/s)
• Supply 15 ... 24 V DC
• W/o heating
• Measurement Range: 0.3...75 m/s
• Accuracy: 1% of value or 0.99999 (4...20 m/s)
• IP 55
• 2 years warranty
Datasheet
Hint: please do not forget to order a sensor cable (by default this comes incl. connector mounting) at the length needed: cable w/ connector[TAB:Alternative Models]
4.3351.00.000
4.3351.00.140
4.3351.00.141
4.3351.00.161
4.3351.10.000
4.3351.10.140
4.3351.10.161
For further information please contact us or look at Documents.
[TAB:Documents]4.3351.x0.140-173_Wind_Transmitter_First_Class_Advanced_analogue_eng.pdf
4.3351.x0.140-173_WG-Geber-firstclass-advanced_analog_deu.pdf
Thies-First-Class-Advanced-Data-Sheet-Brief-en.pdf
For further information please contact us or check the OEM homepage for most recent information.