Cables (shielded) including mounting of connector(s) / plugs / jacks for sensors bought
• per /5m
• Shielded LiYCY x*0.5mm^2 (about 20 gauge)
• Includes mounting of sensor-specific connectors / plugs / jacks
• Sensor-specific wiring scheme included
• Line-to-line calibration according to IEC, MEASNET and FGW recommendations
• Length configured according to measurement heights
• Labelling provided for easy plug&play installation on site
Datasheet
During the order process "field: comments" please let us know, which sensor you plan to install at what height! Please thereby also take into account the length of the booms always when selecting the cable length accordingly.
The price mentioned includes the fitting of a corresponding, sensor-specific standard plug (jack or connector), if being default scope of the sensor delivery. The price mentioned includes an additional set of connectors (male and female) being confectioned as part of the (extension) cable ordered here, in case the sensor, for which the cable is ordered, by default has open-ended wires and no connector is plugged directly to the sensor.
If a cable is ordered only but without sensor, 10 EUR will be charged additionally per connector to be fitted to the cable (male or female).
[TAB:Documents]
For further information please contact us.[TAB:Alternative Models]
LiYCY UV
For further information please contact us or look at Documents.
Cable Length (with connector):
Ohne Kabel (+0 EUR)
Ultrasonic Anemometer Thies - 1D
• Measurement variables possible: horizontal components of wind velocity and wind direction as well as the virtual temperature in 1 dimension
• Wind measurement range: [0 ... 75 m/s]
• Wind direction measurement range: 0° (1°) / 180° (181°) and "calm"
• Virtual temperature measurement range: - 50°C ... +70°C
• Survival wind speed: min. 80 m/s for min. 30 minutes
• Accuracy in rms, mean over 360° (wind speed): ≤ 5m/s: ± 0.1 m/s, > 5 m/s: ± 2%
• Accuracy virtual temperature): ± 5K to 35 m/s
• Resolution (wind speed): 0.1 m/s (except telegrams 6, 7 & 10),
Ultrasonic Anemometer Thies - 2D
• Measurement variables possible: horizontal components of wind velocity and wind direction as well as the virtual temperature in 2 dimensions
• Standard heating stainless-steel caps
• Wind measurement range: [0.01 ... 75 m/s]
• Wind direction measurement range: 0 ... 360° (0...540°, 0...720° analogue adjustable)
• Virtual temperature measurement range: - 50°C ... +70°C
• Survival wind speed: min. 80 m/s for min. 30 minutes
• Accuracy in rms, mean over 360° (wind speed): ≤ 5m/s: ± 0.1 m/s, > 5 m/s: ± 2%
• Accuracy (wind direction): ± 1.0°
• Accuracy virtual temperature): ± 5K to 35 m/s
• Resolution (wind speed): 0.1 m/s (except telegrams 6 & 10), 0.01 m/s in user-defined telegram 6
• Resolution (wind direction): 1° (except telegrams 6 & 10), < 1° in user-defined telegram 6
• Resolution (virtual temperature): 0.1 K (except telegrams 6 and 10)
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Thread diameter for mounting: 11/2" (~48mm) (adapter 1" to 11/2" optional)
• Extreme high precision
• Maintenance free
• Digital /analogue in- and outputs
• Includes warranty maintaining OEM protection box
• IP 67
Datasheet
[TAB:Alternative Types]
4.3820.3x.xxx
4.3820.4x.xxx
For further information please contact us or look at Documents.
[TAB:Documents]4.382x.xx.xxx_US-Anemometer-2D_d.pdf
4.382x.xx.xxx_US-Anemometer-2D_e.pdf
Thies-Ultra-Sonic-Bestellschlüssel-V3.0_2.pdf
Thies-Ultra-Sonic-Order-Key-V3.0_1.pdf
For further information please contact us or check the OEM homepage for most recent information.
Ultrasonic Anemometer Thies - 3D
• Measurement variables possible: horizontal and vertical components of wind velocity and wind direction as well as the virtual temperature in 3 dimensions
• Advanced heating stainless-steel caps and sensor arms
• Wind measurement range: [0.01 ... 85 m/s]
• Wind direction measurement range: azimuth: 0 ... 360° (0...540°, 0...720° analogue adjustable); elevation: -90° ... +90°
• Virtual temperature measurement range: - 40°C ... +70°C
• Survival wind speed: min. 80 m/s for min. 30 minutes
• Accuracy in rms, mean over 360° (wind speed): ≤ 5m/s: ± 0.1 m/s, > 5 m/s ≤ 35m/s: ± 1% , > 35 m/s ≤ 65m/s: ± 2% , > 65 m/s ≤ 85m/s: ± 3% ,
• Accuracy (wind direction): ± 1° (>1 m/s ≤ 35 m/s), ± 2° (>35 m/s ≤ 65 m/s), ± 4° (>65 m/s ≤ 85 m/s)
• Accuracy virtual temperature): ± 0.5K
• Resolution (wind speed): 0.1 m/s (telegrams 1 to 4), 0.01 m/s in user-defined telegrams 5 to 12
• Resolution (wind direction): 1° (in telegrams 1 to 4); 0.1° (in telegrams 5 to 12)
• Resolution (virtual temperature): 0.1 K (in telegrams 1 to 5)
• Sample rate: 0.1 Hz ... 100 Hz
• Operating temperature range: -30°C to 80°C (unheated); -50°C to 80°C (heated)
• Thread diameter for mounting: 11/2" (~48mm) (adapter 1" to 11/2" optional)
• Extreme high precision
• Maintenance free
• Optional with different heating characteristics
• Digital /analogue in- and outputs
• Includes warranty maintaining OEM protection box
• IP 67
Datasheet
[TAB:Alternative Types]
4.3830.4x.xxx
For further information please contact us or look at Documents.
[TAB:Documents]Thies-Ultra-Sonic-Anemometer-3D-engl.pdf
Thies-Ultra-Sonic-Anemometer-Bestellschlüssel-V3.0_2.pdf
Thies-Ultra-Sonic-Anemometer-Order-Key-V3.0_1.pdf
For further information please contact us or check the OEM homepage for most recent information.